Z--HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEM UPGRADE, BUILDING 564, FLEET INTELLIGENCE TRAINING CENTER PACIFIC (FITCPAC), NAVAL BASE POINT LOMA (NBPL), SAN DIEGO, CALIFORNIA (№11516970)

09 dec

Number: 11516970

Country: United States

Source: Federal Business Opportunities


Link to original

To view links to the source need to register

Publication date


09-12-2018

Description


Z--HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEM UPGRADE, BUILDING 564, FLEET INTELLIGENCE TRAINING CENTER PACIFIC (FITCPAC), NAVAL BASE POINT LOMA (NBPL), SAN DIEGO, CALIFORNIASolicitation Number: N6247314D0003X245
Agency: Department of the Navy
Office: Naval Facilities Engineering Command
Location: NAVFAC SOUTHWEST, POINT LOMA FEAD/CODE ROPML

Solicitation Number: N6247314D0003X245

Notice Type: Award Notice

Contract Award Date: December 7, 2018

Contract Award Number: N6247314D0074N6247319F4129

Contract Award Dollar Amount: 1573222

Contract Line Item Number: 0001

Contractor Awardee: Preferred Construction Company, Inc. (DUNS 018663095)
5199 E. Pacific Coast Highway, Suite 513
Long Beach, CA 90804

Synopsis: Added: Dec 08, 2018 9:24 am Competed under NAVFAC SW Heating, Ventilation, and Air Conditioning (HVAC) III Multiple Award Construction Contract (MACC) Group 0072 - Contract N62473-14-D-0003-X245



The purpose of this procurement is to provide Command Navy Region South West (CNRSW) a complete and useable Heating, Ventilation, and Air Conditioning (HVAC) system at Building 554, Harbor Drive Annex (HDA), Naval Base Point Loma (NBPL), San Diego, California. The two existing chiller units, boiler unit, and three rooftop air handling units will need to be replaced with a DX heat pump system as well as fan coil units in Rooms 150, 152, 159, 160, 161, 162, 163, 165 and 166.



Type of work/projects may include, but is not limited to: Design DX systems to replace the three air handling units currently serving the building.

Provide a design that provides the use of one air cooled chiller and one boiler to serve fan coil units in rooms 150, 152, 159, 160, 161, 162, 163, 165 and 166. Design shall provide the combining of chilled water systems to one outdoor air cooled chiller and one boiler. Provide new pumps, expansion tanks, hot water storage tanks, valves and piping to create a comprehensive system. Design and construct heating and cooling system to all spaces supplied by the existing CW system.